| AC Input Alarms, Signal Conditioners, Transmitters | ||||
|---|---|---|---|---|
Click on model numbers below for data sheets and application information ![]() |
Reference Info ![]() Alarm Terminology Deadband Relay Protection & EMI Suppression RFI / EMI Heater Break Alarm Motor Current Monitor & Over Current Shutdown Monitor & Display AC Motor Load Monitor Computer & Process Status Monitoring Motor Speed Using Current |
|||
| Model | Input | Output | Features | |
API 1600 GAC Input Single Alarm Trip |
Specify input range Factory configured 0-50 mVAC to 0-300 VAC 0-1 mAAC to 0-900 mAAC With 5A shunt option 0-900 mAAC to 0-5 AAC |
1 DPDT 7A relay Field adjustable setpoint Specify alarm type See data sheet for alarm options |
|
|
API 1620 GAC Input Dual Alarm Trip |
2 SPDT 7A relays Field adjustable setpoints Specify alarm type See data sheet for alarm options |
|||
API 6010 GAC to DC Transmitter Isolated |
Specify input range Factory configured 0-50 mVAC to 0-300 VAC 0-1 mAAC to 0-900 mAAC |
Specify output range Factory configured Others available 0-1 V 0-5 V 1-5 V 0-10 V ±5 V ±10 V 0-1 mA 0-20 mA 4-20 mA |
|
|
API 6010 G 5AAC to DC Transmitter Isolated |
Specify input range Factory configured Others available 0-1 AAC 0-2 AAC 0-3 AAC 0-5 AAC |
Specify output range Factory configured Others available 0-1 V 0-5 V 1-5 V 0-10 V ±5 V ±10 V 0-1 mA 0-20 mA 4-20 mA |
|
|
APD 6010AC to DC Transmitter True RMS Isolated
|
Specify input range Factory configured 0-50 mVAC to 0-300 VAC 0-1 mAAC to 0-1000 mAAC |
Specify output range Factory configured Others available 0-1 V 0-5 V 1-5 V 0-10 V ±5 V ±10 V 0-1 mA 0-20 mA 4-20 mA |
|
|
APD 6380Field Selectable Minuteman Setup AC to DC Transmitter True RMS Isolated
|
Hundreds of field configurable input ranges 0-40 mVAC to 0-300 VAC 0-4 mAAC to 0-200 mAAC APD 6380 ranges
|
18 field configurable output ranges 0-1 V to ±10 V 0-2 mA to 0-20 mA 4-20 mA Others available |
|
|
API 6380 GField Selectable Minuteman Setup AC to DC Transmitter Isolated |
20 field configurable input ranges 0-50 mVAC to 0-250 VAC 0-5 mAAC to 0-200 mAAC For >200mAAC to 5 Amps use socket/shunt resistor API-008-5A |
16 field configurable output ranges 0-1 V to ±10 V 0-2 mA to 0-20 mA 4-20 mA |
|
![]() |
API 6380 G HVField selectable Minuteman setup AC to DC Transmitter Isolated, High Voltage Input |
24 field configurable input ranges Same as API 6380 but with 0-300 VAC, 0-400 VAC, 0-500 VAC, 0-600 VAC input ranges in addition to standard ranges |
16 Field configurable output ranges 0-1 V to ±10 V 0-2 mA to 0-20 mA 4-20 mA |
||
API 6380 G SField Selectable Minuteman Setup True RMS AC to DC Transmitter Isolated |
20 field configurable input ranges 0-50 mVAC to 0-250 VAC 0-5 mAAC to 0-200 mAAC For >200mAAC to 5 Amps use socket/shunt resistor API-008-5A |
16 field configurable output ranges 0-1 V to ±10 V 0-2 mA to 0-20 mA 4-20 mA |
|
![]() |
API 6380 G SHVField Selectable Minuteman Setup True RMS AC to DC Transmitter Isolated, High Voltage Input |
24 field configurable input ranges Same as API 6380 S but with 0-300 VAC, 0-400 VAC, 0-500 VAC, 0-600 VAC input ranges in addition to standard ranges |
16 field configurable output ranges 0-1 V to ±10 V 0-2 mA to 0-20 mA 4-20 mA |
||