| Absolute Process Instruments, Inc. Signal Conditioners, Signal Isolators, Process Transmitters 800-942-0315 |
Solutions and Support You Can Depend On! |
|||
![]() |
![]() |
![]() |
![]() |
![]() |
|
|
||||
| DC Input Signal Conditioners & Transmitters | ||||
|---|---|---|---|---|
|
Reference Info ![]() Ground Loops RFI / EMI Application Examples ![]() Monitoring Motor Speed Using a PLC Building Heat SCR Control Manual Override of Computer Control Monitor Pressure with a PLC Control & Monitor with One Flow Meter Monitor Product Moved by Conveyor Pharmaceutical Process Validation |
|||
| Model | Input | Output | Features | |
API 2000 SeriesDuoPak® Two Channel Isolated Transmitter |
Specify Input Type and Range for Each Channel Factory Configured Choose Any Two: DC voltage or current AC voltage or current RTD Frequency Potentiometer Strain Gauge See data sheet for input specifications and model numbers |
Specify Output Range for Each Channel Factory Configured 0-1 V, 0-5 V, 1-5 V, 0-10 V ±5 V, ±10 V 0-1 mA, 0-20 mA, 4-20 mA Others available |
|
![]() |
API 4300 GIsolated DC-DC Transmitter with Loop Power Supply |
Specify Input Range Factory Configured 0-100 mVDC to 0-100 VDC ±100 mVDC to ±10 VDC 0-1 mADC to 0-900 mADC Others available |
Specify Output Range Factory Configured 0-1 V, 0-5 V, 1-5 V, 0-10 V ±5 V, ±10 V 0-1 mA, 0-20 mA, 4-20 mA Others available |
|
![]() |
APD 4300 PLC is pre-configured for 4-20 mA I/O
|
Specify Input Range
|
Specify Output Range Others available |
|
Removable Plugs!
![]() |
API 4310 GIsolated DC-DC Transmitter Narrow Input Span with Loop Power Supply |
Specify Input Range Factory Configured 0-10 mVDC to 0-100 mVDC ±50 mVDC 0-10 0 μADC to 0-1 mADC Others available |
Specify Output Range Factory Configured 0-1 V, 0-5 V, 1-5 V, 0-10 V ±5 V, ±10 V 0-1 mA, 0-20 mA, 4-20 mA Others available |
|
![]() |
API 4380 GField Selectable Minuteman Setup Isolated DC-DC Transmitter with Loop Power Supply |
24 Field Configurable Inputs 0-50 mVDC to ±10 VDC 0-1 mADC to 0-20 mADC Others available |
16 Field Configurable Outputs 0-1 V to ±10 V 0-2 mA to 0-20 mA 4-20 mA |
|
![]() |
API 4380 GHV3Field Selectable Minuteman Setup Isolated DC-DC Transmitter High Voltage Input |
24 Field Configurable Inputs 0-1 VDC to ±200 VDC Others available |
16 Field Configurable Outputs 0-1 V to ±10 V 0-2 mA to 0-20 mA 4-20 mA |
|
![]() |
APD 4380Field Selectable Minuteman Setup Isolated DC-DC Transmitter |
53 Field Configurable Input Ranges 0-10 mVDC to 0-50 VDC ±10 mV to ±10 VDC 0-200 μA to 0-50 mADC Others available |
18 Field Configurable Output Ranges 0-1 V to ±10 V 0-2 mA to 0-20 mA 4-20 mA Others available |
|
Removable Plugs!
![]() |
API 4385 GField Selectable Minuteman Setup Isolated DC-DC Transmitter Wide Ranging with Input Offset with Loop Power Supply |
24 Field Configurable Inputs 0-50 mVDC to 0-20 VDC 0-200 μADC to 0-40 mADC Others available Selectable Zero Offset |
16 Field Configurable Outputs 0-1 V to ±10 V 0-2 mA to 0-20 mA 4-20 mA |
|
![]() |
APD HV-DC Fast Field Selectable Setup Isolated DC-DC Transmitter for High Voltage DC Inputs
|
8 Field Configurable Input Ranges 7 standard plus 1
factory set custom range (specify if required) |
18 Field Configurable Output Ranges 0-1 V, 0-2 V, 0-4 V, 1-5 V, 0-5 V, 0-8 V, 2-10 V, 0-10 V, ±5 V, ±10 V, 0-2 mA, 0-4 mA, 0-8 mA, 2-10 mA, 0-10 mA, 0-16 mA, 4-20 mA, 0-20 mA |
|
Removable Plugs!
![]() |
API 43902 Channel DC-DC Transmitter Isolator |
Specify Input Range Factory Configured 2 Independent Channels 0-100 mVDC to 0-10 VDC 0-1 mADC to 4-20 mADC Others available |
Specify Output Ranges Factory Configured 2 Independent Channels 0-100 mVDC to 0-10 VDC 0-1 mADC to 4-20 mADC |
|
Removable Plugs! |
API 43912 Channel DC-DC Transmitter Isolator Bipolar Output |
Specify Input Range Factory Configured 2 Independent Channels 0-100 mVDC to 0-10 VDC 0-1 mADC to 4-20 mADC Others available |
Specify Output Ranges Factory Configured Bipolar DC Volts 2 Independent Channels ±5 VDC, ±10 VDC Others Available |
||
API 43922 Channel DC-DC Transmitter Isolator Bipolar I/O |
Specify Input Range Factory Configured Bipolar DC Volts or mA 2 Independent Channels ±5 VDC, ±10 VDC Others Available |
Specify Output Ranges Factory Configured Bipolar DC Volts or mA 2 Independent Channels ±5 VDC, ±10 VDC Others Available |
||
| Need a Signal Splitter to convert one input to two or more isolated outputs? | ||||
| Documents for Discontinued Products | ||||
API 4300 DIN, API 4300 DD
|
DC-DC Transmitter. See APD 4300 above | |||
API 4300 DIN PLC, API 4300 DD PLC |
4-20 mA DC-DC Transmitter. See APD 4300 PLC above | |||
API 4380 DIN, API 4380 DD
|
DC-DC Transmitter. See APD 4380 above | |||
API DPI HV-DC |
High Voltage DC-DC Transmitter. See APD HV-DC above | |||
API 4010 G |
Non-Isolated DC-DC Transmitter with Loop Power Supply. See API 4300 G | |||
API 4050 G |
Non-Isolated DC-DC Transmitter Narrow Input Span with Loop Power Supply. See API 4310 G | |||
| Phone: 800-942-0315 or 847-918-3510 | Fax: 800-949-7502 or 847-968-4891 | |
| APi Home Page Copyright © 1999-2010 Absolute Process Instruments, Inc. |
||