| Absolute Process Instruments, Inc. Signal Conditioners, Signal Isolators, Process Transmitters 800-942-0315 |
Solutions and Support You Can Depend On! |
|||
![]() |
![]() |
![]() |
![]() |
![]() |
|
|
||||
| DC Input Signal Conditioners & Transmitters | ||||
|---|---|---|---|---|
Links to similar models
Signal SplittersDC Input Math & Square Root Modules DC Input Alarms 4-20 mA Loop Isolators DC Power Supplies |
Reference Info ![]() Ground Loops RFI / EMI Application Examples ![]() Monitoring Motor Speed Using a PLC Building Heat SCR Control Manual Override of Computer Control Monitor Pressure with a PLC Control & Monitor with One Flow Meter Monitor Product Moved by Conveyor Pharmaceutical Process Validation |
|||
| Model | Input | Output | Features | |
APD 2000DuoPak® Two Channel Isolated Transmitter
|
Specify input range for each channel Factory configured DC voltage or current These versions coming soon, call for availability AC voltage or current RTD Frequency Potentiometer Strain gauge |
Specify output range for each channel Factory configured 0-1 V, 0-5 V, 1-5 V, 0-10 V ±5 V, ±10 V 0-1 mA, 0-20 mA, 4-20 mA Others available |
|
|
API 4300 GIsolated DC-DC Transmitter with Loop Power Supply |
Specify input range Factory configured 0-100 mVDC to 0-100 VDC ±100 mVDC to ±10 VDC 0-1 mADC to 0-900 mADC Others available |
Specify output range Factory configured 0-1 V, 0-5 V, 1-5 V, 0-10 V ±5 V, ±10 V 0-1 mA, 0-20 mA, 4-20 mA Others available |
|
|
APD 4300APD 4300 PLC Factory Ranged Isolated DC-DC Transmitter with I/O Loop Power Supplies APD 4300 PLC is pre-configured for 4-20 mA I/O
|
Specify input range Factory configured 0-100 mVDC to 0-100 VDC ±100 mVDC to ±10 VDC 0-1 mADC to 0-900 mADC 4-20 mA input Others available Milliamp input can be field wired for sink or source
|
Specify output range Factory configured 0-1 V to ±10 VDC, 0-1 mA to 4-20 mA, up to 20 VDC with M09 option, 4-20 mA Output Others available |
|
|
API 4310 GIsolated DC-DC Transmitter Narrow Input Span with Loop Power Supply |
Specify input range Factory configured 0-10 mVDC to 0-100 mVDC ±50 mVDC 0-10 0 μADC to 0-1 mADC Others available |
Specify output range Factory configured 0-1 V, 0-5 V, 1-5 V, 0-10 V ±5 V, ±10 V 0-1 mA, 0-20 mA, 4-20 mA Others available |
|
|
API 4380 GField Selectable Minuteman Setup Isolated DC-DC Transmitter with Loop Power Supply |
24 Field configurable inputs 0-50 mVDC to ±10 VDC 0-1 mADC to 0-20 mADC Others available |
16 Field configurable outputs 0-1 V to ±10 V 0-2 mA to 0-20 mA 4-20 mA |
|
|
API 4380 GHV3Field Selectable Minuteman Setup Isolated DC-DC Transmitter High Voltage Input |
24 field configurable inputs 0-1 VDC to ±200 VDC Others available |
16 field configurable outputs 0-1 V to ±10 V 0-2 mA to 0-20 mA 4-20 mA |
|
![]() |
APD 4380Field Selectable Minuteman Setup Isolated DC-DC Transmitter ![]() |
53 field configurable input ranges 0-10 mVDC to 0-50 VDC ±10 mV to ±10 VDC 0-200 μA to 0-50 mADC Others available |
18 Field configurable output ranges 0-1 V to ±10 V 0-2 mA to 0-20 mA 4-20 mA Others available |
|
|
API 4385 GField Selectable Minuteman Setup Isolated DC-DC Transmitter Wide Ranging with Input Offset with Loop Power Supply |
24 field configurable inputs 0-50 mVDC to 0-20 VDC 0-200 μADC to 0-40 mADC Others available Selectable zero offset |
16 field configurable outputs 0-1 V to ±10 V 0-2 mA to 0-20 mA 4-20 mA |
|
![]() |
APD HV-DCFast Field Selectable Setup Isolated DC-DC Transmitter for High Voltage DC Inputs
|
8 Field configurable input ranges 7 standard plus 1 factory set custom range (specify if required) 0-100 VDC, 0-200 VDC, 0-300 VDC, 0-400 VDC, 0-500 VDC, 0-1000 VDC, 0-1200 VDC, custom |
18 Field configurable output ranges 0-1 V, 0-2 V, 0-4 V, 1-5 V, 0-5 V, 0-8 V, 2-10 V, 0-10 V, ±5 V, ±10 V, 0-2 mA, 0-4 mA, 0-8 mA, 2-10 mA, 0-10 mA, 0-16 mA, 4-20 mA, 0-20 mA |
|
|
APD 4393IsoSplitter DC-DC Signal Isolator-Splitter
|
Specify input range Factory configured 0-10mVDC to 100 VDC, ±50 mV to ±10 VDC, 0-1 mADC to 0-50 mADC, 4-20 mADC Current input may be selectively wired for sinking or sourcing using built-in 15 VDC power supply |
Ch.1: Specify output range Ch.2: Specify output range Factory configured 2 Independent channels 0-1 VDC to 10 VDC, ±1 V to ±10 VDC, 0-1 mADC to 0-25 mADC, 4-20 mADC Current outputs may be selectively wired for sinking or sourcing using built-in 20 VDC power supply. Optional I/O reversal Optional high voltage output to 20 VDC |
|
![]() |
API 4400 G - API 4408 G
|
Specify input ranges Factory configured Input negative is common 0-1 V 0-5 V 1-5 V 0-10 V ±5 V ±10 V 0-20 mA 4-20 mA Others available from 100 mV to 10 VDC |
Specify output range Factory configured Others available 0-1 V 0-5 V 1-5 V 0-10 V ±5 V ±10 V 0-1 mA 0-20 mA 4-20 mA Isolated DC output |
|
![]() |
| API 4400 G: (A+B+C+D)/4 | ||||
| API 4401 G: (A+B+C)/3 | ||||
| API 4402 G: (A+B)/2 | ||||
| API 4403 G: (A+B+C–D)/3 | ||||
| API 4404 G: (A+B–C–D)/2 | ||||
| API 4405 G: A–B–C–D | ||||
| API 4406 G: (A+B–C)/2 | ||||
| API 4407 G: A–B–C | ||||
| API 4408 G: A–B | ||||
API 4440 GDC to DC Transmitter with Square Root Extraction |
Specify input range Factory configured 0-50 mVDC to 0-200 VDC 0-1 mADC to 0-50 mADC |
Specify output range Factory configured Others available 0-1 V 0-5 V 1-5 V 0-10 V ±5 V ±10 V 0-1 mA 0-20 mA 4-20 mA |
|
![]() |
| Documents for Discontinued Products | ||||
API 4300 DIN,API 4300 DD |
DC-DC Transmitter. See APD 4300 above. | |||
API 4300 DIN PLC, API 4300 DD PLC |
4-20 mA DC-DC Transmitter. See APD 4300 PLC above. | |||
API 4380 DIN,API 4380 DD |
DC-DC Transmitter. See APD 4380 above. | |||
API DPI HV-DC |
High Voltage DC-DC Transmitter. See APD HV-DC above | |||
API 4010 G |
Non-Isolated DC-DC Transmitter with Loop Power Supply. See API 4300 G. | |||
API 4050 G |
Non-Isolated DC-DC Transmitter Narrow Input Span with Loop Power Supply. See API 4310 G | |||
API 4390 DIN,API 4391 DIN, API 4392 DIN |
2 Channel DC-DC Transmitter Isolators. See APD 2000. | |||
API 4393 DIN G |
IsoSplitter DC-DC Signal Isolator-Splitter. See APD 4393. | |||
| Phone: 800-942-0315 or 847-918-3510 | Fax: 800-949-7502 or 847-968-4891 | |
| APi Home Page Copyright © 1999-2012 Absolute Process Instruments, Inc. |
||