RTD Input Transmitters, Indicators, and Alarms
Click on model numbers below for data sheets
Scroll to bottom for discontinued API 4000 G and API 4001 G datasheets
Lifetime Warranty on API and APD Series
Reference Info pdf
Alarm Terminology
Deadband
Relay Protection & EMI Suppression
Application Examples pdf
Monitor & Control Differential Temperature
Motor Overheating Alarm & Shutdown
Maintain Constant ΔT Across a Heat Exchanger
Phase Separator Water Level Control
Transmitters Input Output Features
pdf Sineax V624

Programmable
Isolated RTD or
T/C to DC Transmitter
Microprocessor Based
RTD
2-, 3-, or 4-wire
100 Ω 0.00385α
100 Ω 0.003916α

T/C types
J, K, T, E, R, S, N, B, W5, W3, L, U

Thermistor

Custom
Specify if Current or Voltage
Output
0-2 mA to
0-20 mA,
20-0 mA
0-1 V to
0-10 V,
10-0 V
  • PC Programmable
  • Reverse Output Programmable
  • Custom Input Linearization
  • Programmable Sensor Fault Response
  • Removable Plugs
  • 3.7 kV Input/Output/Power Isolation
  • 24-60 or 85-230 VAC/VDC Powered
pdf Instructions
Software
CESineax V624
pdf API 4001 G L

Isolated &
Linearized
RTD Temperature
to DC Transmitter
Specify RTD Type and Temperature Range
Factory Configured
10 Ω Copper
100 Ω 0.00385α
100 Ω 0.00391α
2000 Ω Ni-Fe
Also available in °C
–100-300°F
0-300°F
0-400°F
0-500°F
0-600°F
0-1000°F
0-1500°F
Specify Output Range
Factory Configured
Others available
0-1 V
0-5 V
1-5 V
0-10 V
±5 V
±10 V
0-1 mA
0-20 mA
4-20 mA
  • RTD Linearization
  • Hot-Swappable Plug-In Design
  • I/O LoopTracker LEDs
  • Output Test Button
  • Full I/O/Power Isolation
  • 2-Wire or 3-Wire RTD
  • Lead Wire Compensation for 3-Wire
  • Uses API-008 8-Pin Socket
  • 115 VAC Powered
  • A230 option for 230 VAC Power
  • D option for 9-30 VDC Power (+$60)
UL listed

Api 4001G L
pdf API 4001 G SA-B

Differential RTD Temperature to
DC Transmitter
Non-Isolated
Specify Temperature Range
Factory Configured
ΔT from 20F° to 900F° or
10C° to 500C°
Two 100 Ω 0.00385α RTDs
Specify Output Range
Factory Configured
Others available
0-1 V
0-5 V
1-5 V
0-10 V
±5 V
±10 V
0-20 mA
4-20 mA
  • Hot-Swappable Plug-In Design
  • I/O LoopTracker LEDs
  • Output Test Button
  • 2-Wire or 3-Wire RTD
  • Lead Wire Compensation for 3-Wire
  • Linearized RTD
  • Inputs Can Be Field Calibrated
  • Uses API-011 11-Pin Socket
  • 115 VAC Powered
  • A230 option for 230 VAC Power
  • D option for 9-30 VDC Power (+$60)
UL listed

Api 4001G SAB
pdf API 2000 Series
DuoPak
®

Two Channel Isolated
Transmitte
r

Specify Input Type and Range for Each Channel
Factory Configured
Choose Any Two:
DC voltage or current
AC voltage or current
RTD
Frequency
Potentiometer
Load Cell/Strain Gauge
See data sheet for input specifications and model numbers

Specify Output Range for Each Channel
Factory Configured
0-1 V,  0-5 V, 
1-5 V,  0-10 V
±5 V,  ±10 V
0-1 mA,  0-20 mA,  4-20 mA
Others available
  • Two Independent Channels
  • I/O LoopTracker LEDs
  • Output Test Buttons
  • Full I/O/Power Isolation
  • Removable Plugs
  • DIN Rail or Surface Mount
  • 55 mm Wide
  • 80-265 VAC or 48-300 VDC Powered
  • API 20xx DD for 9-30 VDC/ 10-32 VAC Power (+$60)
DuoPak
pdf T16L Series
(F16LT)

ThermoPro®
Indicating RTD Transmitter


Specify RTD Length and Fixed or Spring-Loaded RTD
Temperature Range
–58.0°F to 392.0°F or
–50.0°C to 200.0°C
Selectable °F or °C
See data sheet for model numbers
4-20 mA Output is User Configurable Over the Temperature Range
  • User-Programmable 4-20 mA Output Range
  • 0.1 Degree Display Resolution
  • Precision RTD Element
  • NEMA 4X Housing
  • 2-Wire Design
  • Powered by 8-32 VDC 4-20 mA Current Loop
  • 316 Stainless Steel Probe
  • 1/2" NPT Fitting for Standard Thermowells
  • Spring-Loaded Probe for use with Thermowells
ThermoPro
Indicators Input Output Features
pdf T16B Series

ThermoPro®
Battery Powered RTD Temperature Indicator


new product
Specify RTD Length and Fixed or Spring-Loaded RTD
Temperature Range
–58.0°F to 392.0°F or
–50.0°C to 200.0°C
Selectable °F or °C
See data sheet for model numbers
None
  • 0.1 Degree Display Resolution
  • Precision RTD Element
  • NEMA 4X Housing
  • Powered by Two AA batteries (included)
  • 316 Stainless Steel Probe
  • 1/2" NPT Fitting for Standard Thermowells
  • Spring-Loaded Probe available for use with Thermowells
ThermoPro battery powered
Alarms Input Output Features
pdf T16ADA Series

ThermoPro®
Indicating RTD Temperature Alarm


new product
Specify RTD Length and Fixed or Spring-Loaded RTD
Temperature Range
–58.0°F to 392.0°F or
–50.0°C to 200.0°C
Selectable °F or °C
See data sheet for model numbers
2 SPDT relays,
1 A @ 24 VDC,
0.5 A @ 115 VAC,
Non-inductive,
Fully programmable
  • User-Programmable Alarm Relays
  • 0.1 Degree Display Resolution
  • Precision RTD Element
  • NEMA 4X Housing
  • Powered by 8-32 VDC, 10-32 VAC
  • 316 Stainless Steel Probe
  • 1/2" NPT Fitting for Standard Thermowells
  • Spring-Loaded Probe for use with Thermowells
ThermoPro alarm
pdf API 1400 G

RTD Input Single Alarm Trip
Specify RTD type and Temperature Range
Factory Configured
10 Ω to 2000 Ω RTD including
100 Ω 0.00385α
100 Ω 0.00391α,
10 Ω Cu,
1000 Ω Ni-Fe,
120 Ω Ni or Special
1 DPDT 7A
Contact Set
Field Adjustable
Specify Alarm Type
See data sheet for alarm options
  • Hot-Swappable Plug-In Design
  • LoopTracker LED for Input
  • Alarm Status LEDs
  • Push to Test/Reset
  • 2-Wire or 3-Wire RTD
  • Lead Wire Compensation for 3-Wire
  • Uses API-011 11-Pin Socket
  • 115 VAC Powered
  • A230 option for 230 VAC Power
  • D option for 9-30 VDC Power (+$60)
UL listed

Api 1400G
pdf API 1420 G

RTD Input Dual Alarm Trip
2 SPDT 7A
Contact Sets
Field Adjustable
Specify Alarm Type
See data sheet for alarm options

pdf APD 1400

RTD Input Single Alarm Trip

New!

Specify RTD type and Temperature Range
Factory Configured
10 Ω to 2000 Ω RTD including
100 Ω 0.00385α
100 Ω 0.00391α,
10 Ω Cu,
1000 Ω Ni-Fe,
120 Ω Ni or Special

Single setpoint dual SPDT Form C 8A contact set
Field Adjustable
Specify Alarm Type
Standard: HI alarm, non-latching, normal acting
Options: LO alarm, latching, reverse acting
See data sheet for alarm options

  • DIN Rail Mount without Tools
  • LoopTracker LED for Input
  • Alarm Status LEDs
  • Push to Test/Reset
  • 2-Wire or 3-Wire RTD
  • Lead Wire Compensation for 3-Wire
  • Universal Power
  • D option for 9-30 VDC, 10-32 VAC Power
APD 1400

pdf APD 1420

RTD Input Dual Alarm Trip

New!

Specify RTD type and Temperature Range
Factory Configured
10 Ω to 2000 Ω RTD including
100 Ω 0.00385α
100 Ω 0.00391α,
10 Ω Cu,
1000 Ω Ni-Fe,
120 Ω Ni or Special
Two setpoint dual SPDT Form C 8A contact sets
Field Adjustable
Specify Alarm Type
Standard: HI/LO alarm, non-latching, normal acting
Options: LO/LO, HI/HI, LO/HI alarms, latching, reverse acting
See data sheet for alarm options
  • DIN Rail Mount without Tools
  • LoopTracker LED for Input
  • Alarm Status LEDs
  • Push to Test/Reset
  • 2-Wire or 3-Wire RTD
  • Lead Wire Compensation for 3-Wire
  • Universal Power
  • D option for 9-30 VDC, 10-32 VAC Power
APD1420

pdf APD 1430

RTD Input Band Alarm Trip

New!

Specify RTD type and Temperature Range
Factory Configured
10 Ω to 2000 Ω RTD including
100 Ω 0.00385α
100 Ω 0.00391α,
10 Ω Cu,
1000 Ω Ni-Fe,
120 Ω Ni or Special
Two setpoint dual SPDT Form C 8A contact sets
Field Adjustable
Specify Alarm Options
Standard: Band alarm (both alarms trip if outside LO and HI
trip points), non-latching, normal acting
Options: Inverse band alarm, latching, reverse acting
See data sheet for alarm options
  • DIN Rail Mount without Tools
  • LoopTracker LED for Input
  • Alarm Status LEDs
  • Push to Test/Reset
  • 2-Wire or 3-Wire RTD
  • Lead Wire Compensation for 3-Wire
  • Universal Power
  • D option for 9-30 VDC, 10-32 VAC Power
APD 1430
Documents for Discontinued Products
pdf API 4000 G RTD or T/C to DC Transmitter. Replaced by the Sineax V624.
pdf API 4001 G Non-Isolated RTD-DC Transmitter. Replaced by the API 4001 GL