| RTD Input Alarms and Transmitters | ||||
|---|---|---|---|---|
| Download pdf with all products on this page RTD Input Alarms and Transmitters Click on model numbers below for data sheets |
Hot-Swappable Plug-In Design LoopTracker® LEDs Output Test Lifetime Warranty |
Reference Info Alarm Terminology Deadband Relay Protection & EMI Suppression |
||
| Model | Input | Output | Features | |
| API 2000 Series DuoPak® Two Channel Isolated Transmitter ![]() |
Specify Input Type and Range for Each Channel Factory Configured Choose Any Two: DC voltage or current AC voltage or current RTD Frequency Potentiometer See data sheet for input specifications and model numbers |
Specify Output Range for Each Channel Factory Configured 0-1 V, 0-5 V, 1-5 V, 0-10 V ±5 V, ±10 V 0-1 mA, 0-20 mA, 4-20 mA Others available |
|
![]() |
| F16LT Series ThermoPro® Indicating RTD Transmitter ![]() |
Specify RTD Length and Fixed or Spring-Loaded RTD Temperature Range –58.0°F to 392.0°F or –50.0°C to 200.0°C Selectable °F or °C See data sheet for model numbers |
4-20 mA Output is User Configurable Over the Temperature Range |
|
![]() |
| API 1400 G RTD Input Single Alarm Trip |
Specify RTD type and Temperature Range Factory Configured 10 Ω to 2000 Ω RTD including 100 Ω 0.00385α 100 Ω 0.00391α, 10 Ω Cu, 1000 Ω Ni-Fe, 120 Ω Ni or Special |
1 DPDT 7A Contact Set Field Adjustable Specify Alarm Type See data sheet for alarm options |
|
![]() |
| API 1420 G RTD Input Dual Alarm Trip |
2 SPDT 7A Contact Sets Field Adjustable Specify Alarm Type See data sheet for alarm options |
|||
| Sineax V624 Programmable Isolated RTD or T/C to DC Transmitter Microprocessor Based |
RTD 2-, 3-, or 4-wire 100 Ω 0.00385α 100 Ω 0.003916α T/C types J, K, T, E, R, S, N, B, W5, W3, L, U Thermistor Custom |
Specify if Current or Voltage Output 0-2 mA to 0-20 mA, 20-0 mA 0-1 V to 0-10 V, 10-0 V |
Software |
![]() ![]() |
| API 4001 G L Isolated & Linearized RTD Temperature to DC Transmitter |
Specify RTD Type and Temperature Range Factory Configured 10 Ω Copper 100 Ω 0.00385α 100 Ω 0.00391α 2000 Ω Ni-Fe Also available in °C –100-300°F 0-300°F 0-400°F 0-500°F 0-600°F 0-1000°F 0-1500°F |
Specify Output Range Factory Configured Others available 0-1 V 0-5 V 1-5 V 0-10 V ±5 V ±10 V 0-1 mA 0-20 mA 4-20 mA |
|
![]() |
| API 4001 G SA-B Differential RTD Temperature to DC Transmitter Non-Isolated |
Specify Temperature Range Factory Configured ΔT from 20F° to 900F° or 10C° to 500C° Two 100 Ω 0.00385α RTDs |
Specify Output Range Factory Configured Others available 0-1 V 0-5 V 1-5 V 0-10 V ±5 V ±10 V 0-20 mA 4-20 mA |
|
![]() |
| Discontinued Products | ||||
| API 4000 G | RTD or T/C to DC Transmitter. Replaced by the Sineax V624. | |||
| API 4001 G | Non-Isolated RTD-DC Transmitter. Replaced by the API 4001 GL | |||