| RTD Input Transmitters, Indicators, and Alarms | ||||
|---|---|---|---|---|
| Click on model numbers below for data sheets Scroll to bottom for discontinued API 4000 G and API 4001 G datasheets Lifetime Warranty on API and APD Series |
Reference Info ![]() Alarm Terminology Deadband Relay Protection & EMI Suppression Application Examples ![]() Monitor & Control Differential Temperature Motor Overheating Alarm & Shutdown Maintain Constant ΔT Across a Heat Exchanger Phase Separator Water Level Control |
|||
| Transmitters | Input | Output | Features | |
Sineax V624Programmable Isolated RTD or T/C to DC Transmitter Microprocessor Based |
RTD 2-, 3-, or 4-wire 100 Ω 0.00385α 100 Ω 0.003916α T/C types J, K, T, E, R, S, N, B, W5, W3, L, U Thermistor Custom |
Specify if Current or Voltage Output 0-2 mA to 0-20 mA, 20-0 mA 0-1 V to 0-10 V, 10-0 V |
InstructionsSoftware |
![]() ![]() |
API 4001 G LIsolated & Linearized RTD Temperature to DC Transmitter |
Specify RTD Type and Temperature Range Factory Configured 10 Ω Copper 100 Ω 0.00385α 100 Ω 0.00391α 2000 Ω Ni-Fe Also available in °C –100-300°F 0-300°F 0-400°F 0-500°F 0-600°F 0-1000°F 0-1500°F |
Specify Output Range Factory Configured Others available 0-1 V 0-5 V 1-5 V 0-10 V ±5 V ±10 V 0-1 mA 0-20 mA 4-20 mA |
|
![]() |
API 4001 G SA-BDifferential RTD Temperature to DC Transmitter Non-Isolated |
Specify Temperature Range Factory Configured ΔT from 20F° to 900F° or 10C° to 500C° Two 100 Ω 0.00385α RTDs |
Specify Output Range Factory Configured Others available 0-1 V 0-5 V 1-5 V 0-10 V ±5 V ±10 V 0-20 mA 4-20 mA |
|
![]() |
API 2000 SeriesDuoPak® Two Channel Isolated Transmitter |
Specify Input Type and Range for Each Channel |
Specify Output Range for Each Channel Factory Configured 0-1 V, 0-5 V, 1-5 V, 0-10 V ±5 V, ±10 V 0-1 mA, 0-20 mA, 4-20 mA Others available |
|
![]() |
T16L Series(F16LT) ThermoPro® Indicating RTD Transmitter |
Specify RTD Length and Fixed or Spring-Loaded RTD Temperature Range –58.0°F to 392.0°F or –50.0°C to 200.0°C Selectable °F or °C See data sheet for model numbers |
4-20 mA Output is User Configurable Over the Temperature Range |
|
![]() |
| Indicators | Input | Output | Features | |
T16B SeriesThermoPro® Battery Powered RTD Temperature Indicator ![]() |
Specify RTD Length and Fixed or Spring-Loaded RTD Temperature Range –58.0°F to 392.0°F or –50.0°C to 200.0°C Selectable °F or °C See data sheet for model numbers |
None |
|
![]() |
| Alarms | Input | Output | Features | |
T16ADA SeriesThermoPro® Indicating RTD Temperature Alarm ![]() |
Specify RTD Length and Fixed or Spring-Loaded RTD Temperature Range –58.0°F to 392.0°F or –50.0°C to 200.0°C Selectable °F or °C See data sheet for model numbers |
2 SPDT relays, 1 A @ 24 VDC, 0.5 A @ 115 VAC, Non-inductive, Fully programmable |
|
![]() |
API 1400 GRTD Input Single Alarm Trip |
Specify RTD type and Temperature Range Factory Configured 10 Ω to 2000 Ω RTD including 100 Ω 0.00385α 100 Ω 0.00391α, 10 Ω Cu, 1000 Ω Ni-Fe, 120 Ω Ni or Special |
1 DPDT 7A Contact Set Field Adjustable Specify Alarm Type See data sheet for alarm options |
|
![]() |
API 1420 GRTD Input Dual Alarm Trip |
2 SPDT 7A Contact Sets Field Adjustable Specify Alarm Type See data sheet for alarm options |
|||
|
Specify RTD type and Temperature Range Factory Configured 10 Ω to 2000 Ω RTD including 100 Ω 0.00385α 100 Ω 0.00391α, 10 Ω Cu, 1000 Ω Ni-Fe, 120 Ω Ni or Special |
Single setpoint dual SPDT Form C 8A contact set |
|
![]() |
|
Specify RTD type and Temperature Range Factory Configured 10 Ω to 2000 Ω RTD including 100 Ω 0.00385α 100 Ω 0.00391α, 10 Ω Cu, 1000 Ω Ni-Fe, 120 Ω Ni or Special |
Two setpoint dual SPDT Form C 8A contact sets Field Adjustable Specify Alarm Type Standard: HI/LO alarm, non-latching, normal acting Options: LO/LO, HI/HI, LO/HI alarms, latching, reverse acting See data sheet for alarm options |
|
![]() |
|
Specify RTD type and Temperature Range Factory Configured 10 Ω to 2000 Ω RTD including 100 Ω 0.00385α 100 Ω 0.00391α, 10 Ω Cu, 1000 Ω Ni-Fe, 120 Ω Ni or Special |
Two setpoint dual SPDT Form C 8A contact sets Field Adjustable Specify Alarm Options Standard: Band alarm (both alarms trip if outside LO and HI trip points), non-latching, normal acting Options: Inverse band alarm, latching, reverse acting See data sheet for alarm options |
|
![]() |
| Documents for Discontinued Products | ||||
API 4000 G |
RTD or T/C to DC Transmitter. Replaced by the Sineax V624. | |||
API 4001 G |
Non-Isolated RTD-DC Transmitter. Replaced by the API 4001 GL | |||